Frequency Inverter

SCH2100 Series inverters

SCH2100 Series invertersThe newest generation of inverters : general purpose, for wide range applications, from the simpliest speed control to the most complex process automation system. Modular conce

SCH2100 Series inverters

The newest generation of inverters : general purpose, for wide range applications, from the simpliest speed control to the most complex process automation system. Modular concept, easy configurable,a lot of different setup parameters make this inverter series suitable for the high volume OEM-marketsingle applications as well. Assembled on modern high speed lines, using high quality components from first class vendors. This is the guarantee for cost efficiency, reliabilityabsolute quality. Green production: through environmentally friendly operating processes, a must, for a product which final destination is protecting the environment by saving energyresources. All products are compliant with international standards.CE,UL individual approvals, performedcertified by independent bodies, give the customer the trust in a world class product.

Technical product data

 ItemsContents
  InputRated Voltage Range 3-phase 380-480V (+10%, -15%) note 1
3-phase 220V~240V ±15%
1-phase 220-240V ±15%
Rated Frequency50/60Hz
 OutputRated Voltage Range3-phase 0-INPUT (V)
Frequency Range0.50 590.0Hz (In SVC control mode, the max frequency should be lower than 500Hz.)
Control ModeCarrier Frequency800 16000Hz; Fixed carrier-wave and random carrier-wave can be selected by F159.
Input Frequency ResolutionDigital setting: 0.01Hz, analog setting: max frequency X 0.1%
Control ModeFor induction motor:
SVC (open-loop vector control) control, V/F control
VC (Closed-loop vector control) control
For PMSM: SVC (open-loop vector control) control
Start Torque0.5 Hz / 150% (SVC) 0Hz/180% (VC),5% of rated speed/100% of rated torque (PMSM SVC)
Speed-control Scope1:100 (SVC), 1:1000 (VC), 1:20 (in PMSM SVC)
Steady Speed Precision±0.5% SVC), ±0.02%(VC)
Torque Control Precision±5%
Overload Capacity150% rated current, 60 seconds.
Torque ElevatingAuto torque promotion, Manual Torque Promotion includes 1-20 curves.
V/F Curve3 kinds of modes: beeline type, square type and under-defined V/F curve
Startup mode Direct startup, speed track startup (V/F control)
DC BrakingDC braking frequency: 0.20-50.00 Hz,braking time: 0.00~30.00s
Jogging ControlJogging frequency range: min frequency~ max frequency, jogging acceleration/decelerationtime: 0.1~3000s
Auto Circulating Running and multistage speed runningAuto circulating running or terminals control can realize 15-stage speed running.
Built-in PID adjustingEasy to realize a system for process closed-loop control
Auto voltage regulation (AVR)When the source voltage changes, the modulation rate can be adjusted automatically,so thatthe output voltage is unchanged.
 Operation FunctionFrequency SettingPotentiometer or external analog signal (0 5V, 0 10V, 0 20Ma); keypad (terminal)▲ ▼keys, external control logic and automatic circulation setting
Start/Stop ControlTerminal control, keypad control or communication control.
Running Command Channels3 kinds of channels from keypad panel, control terminal and MODBUS
Frequency SourceFrequency sources: given digit, given analog voltage, given analog current and givenMODBUS
Accessorial frequency Source7 kinds of accessorial frequency
 OptionalBuilt-in EMI filter, built-in braking unit, Modbus, tele-control panel
Protection FunctionInput phase loss, Output phase loss, input under-voltage, DC over-voltage, over-current, inverter over-load, motor over-load,current stall, over-heat, external disturbance, under-load, pressure control, analog line disconnected, PG line disconnection,keypad disconnection, oPEn protection, STO and STO1. 
 DisplayKeypad showing present output frequency, present rotate-speed (rpm), present output current, present output voltage, present linearvelocity, types of faults, and parameters for the system and operation; LED indicators showing the current working status of inverter.
Environment ConditionsEquipment LocationIn an indoor location, Prevent exposure from direct sunlight, Free from dust, tangy causticgases, flammable gases, steam or the salt-contented, etc.
Environment Temperature-10℃~+50℃
Environment HumidityBelow 90% (no water-bead coagulation)
Vibration StrengthBelow 0.5g (acceleration)
Height above sea level1000m or below
 Protection levelIP20
Applicable Motor0.2 400kW

Note 1: under different voltage level, user should connect jumper on the pin board, the model of pin board is E2F3UZ00. 1)When input voltage is 380~420VAC, please connect CN2 to CN3 (380V Jumper).

2)When input voltage is 420~480VAC, please connect CN4 to CN5(480V Jumper).The default system is 380~420VAC, if some operation is needed, please power off inverter and contact with profession engineer.

Functions of Control Terminals

TerminalTypeDescriptionFunction
DO1OutputsignalMultifunctionaloutput terminal 1When the token function is valid, the value between this terminaland CM is 0V; when the inverter is stopped, the value is 24V. WhenDO1 is as high-frequency output terminal, the max output frequencyis 100KHz and please do not connect to intermediate relay.The functions ofoutput terminalsshall be definedper manufacturer’svalue. Their initialstate may bechanged throughchanging functioncode
DO2Note 1Multifunctionaloutput terminal 2When the token function is valid, the value between this terminal
and CM is 0V; when the inverter is stopped, the value is 24V
TARelay contacTC is a common point, TB-TC are normally closed contacts, TA-TCare normally open contacts. The contact capacity is 10A/125VAC,NO/NC 3A 250VAC/30VDC.
TB
TC
AO1Vo lt age/ currentoutputIt is connected with frequency meter, speedometer or ammeter externally, and its minus pole is connected with GND. See F423 F426 for details,.
AO2Current outputIt is connected with ammeter externally, and its minus pole is connected with GND. See F427 F430 for details
10VAnalog powersupplySelf contained power supplyInternal 10V self-contained power supply of the inverter provides power toinverter. When used externally, it can only be used as the power supply for voltage control signal, with current restricted below 20mA.
Al1InputSignalVoltage analoginput port When analog speed control is adopted, the voltage or current signal is input through this terminal. The range of voltage input is 0~5V or 0~10V or -10V-10V, and the current input is 0 20mA, the input resistor is 500Ohm, and grounding: GND. If the input is 4 20mA, it can be realized by setting F406=2. The voltage or current signal can be chosen by coding switch. See table 5-2, 5-3 for details, the default setting of AI1 is 0~10V, and the default setting of AI2 is 0~20mA.
Al2Voltage / Currentanalog input por
GNDSelf-contained Powersupply GroundGround terminal of external control signal (voltage control signal or current source control signal) is also the ground of 10V power supply of this inverter.
24VPower supplyControl power supplyPower: 24±1.5V, grounding is CM; current is restricted below 200mA for external use
DI1Digitalinputcontrol terminalJogging terminalWhen this terminal is valid, the inverter will have jogging running. The jogging function of this terminal is valid under both at stopped and running status. This terminal can also be used as high-speed pulse input port. The max frequency is 100KHz.The functions ofinput terminalsshall be definedper manufacturer’value.Otherfunctions can alsobe defined bychanging functioncodes.
 DI2ExternalEmergency StopWhen this terminal is valid, “ESP” malfunction signal will be displayed.
 DI3“FWD” TerminaWhen this terminal is valid, inverter will run forward.
 DI4“REV” TerminalWhen this terminal is valid, inverter will run reversely
 DI5Reset terminalMake this terminal valid under fault status to reset the inverter
 DI6Free-stopMake this terminal valid during running can realize free stop
DI7 Note 1Running terminal When this terminal is in the valid state, inverter will run by the acceleration time.
DI8 Note 1Stop terminalMake this terminal valid during running can realize stop by the deceleration time.
CMCommonportGrounding ofcontrol powersupplyThe grounding of 24V power supply and other control signals.
GND485communicationterminalsGrounding ofdifferential signal Grounding of differential signal
5VPower of differentialsignal Power of differential signal
A+Positive polarity ofdifferential signalStandard: TIA/EIA-485(RS-485)                                                                                                     Communication protocol: Modbus B                                                                                                      Communication rate: 1200/2400/4800/9600/19200/38400/57600bps
 B-Negative polarity of Differential signal

TA TB TC D01 D02 24V CM DI1 DI2 DI3 DI4 DI5 DI6 DI7 DI8 10V AI1 AI2 GND AO1 AO2 GND 5V A+ B-

Note:1.T3 30kW and below 30kW and T2 2.2kw and below 2.2kw inverters have no DO2, DI7 and DI8 control terminals.2.AI1 terminal of T3 30kW and below 30kW and T2 2.2kw and below 2.2kw inverters can only accept voltage signal, the default voltage is 0~10V

Wiring diagram

E2100 Series Wiring diagram

FAQ

Can I get some samples?

Yes, Sample order is available for quality check and market test. But you have to pay the express cost.

 

What's delivery time?

It usually takes about 3-5 working days for small order and 10-15 days for big order.

 

How to solve the quality problems after sales?

Take photos or videos of the problems and send to us.

We will make a satisfied solution for you within 24 hours after we confirm the problems.


热门推荐